857-800 WAGO Temperature signal conditioner for RTD sensors

JUAL 857-800 WAGO Temperature signal conditioner for RTD sensors;

Current and voltage output signal; Configuration via DIP switch; Supply voltage: 24 VDC; 6 mm module width; light gray

857-800 WAGO Temperature signal conditioner for RTD sensors

 

Part Number 857-800
Description Temperature signal conditioner for RTD sensors; Current and voltage output signal; Configuration via DIP switch; Supply voltage: 24 VDC; 6 mm module width; light gray
Manufacturer WAGO
Technical data
Configuration
Configuration options DIP switch
DIP switch
Input
Input signal type Pt sensors
Resistor
Input – RTD sensors
Sensor types (RTD) Pt100
Pt200
Pt500
Pt1000
Sensor connection 2-wire; 3-wire; 4-wire (switchable)
Sensor power supply (RTD) (max.) ≤ 0.5 mA
Measurement range, temperature (RTD) -200 … 850°C
Input – resistors
Input range (resistor) 0 … 1 kΩ; 0 … 4.5 kΩ
Output – analog
Output signal type Current
Voltage
Output signal (voltage) 0 … 5 V; 1 … 5 V; 0 … 10 V; 2 … 10 V
Output signal (current) 0 … 10 mA; 2 … 10 mA; 0 … 20 mA; 4 … 20 mA
Load impedance (voltage output) ≥ 2 kΩ
Load impedance (current output) ≤ 600 Ω
Signal processing
Step response (typ.) 180 ms (2-wire); 360 ms (3-wire)
Measurement error
Transmission error (typ.) ≤ 0.1 % at full measurement span
Transmission error for the set measurement range ≤ ((10 K/set measurement range [K]) + 0.1) %
Temperature coefficient ≤ 0.02 %/K
Supply
Power supply type 24 VDC
Nominal supply voltage US DC 24 V
Supply voltage range ±30 %
Power consumption at nominal supply voltage ≤ 40 mA
Safety and protection
Protection type IP20
Test voltage
Test voltage (input/output/supply) AC 2.5 kV; 50 Hz; 1 min
Connection data
Connection technology Push-in CAGE CLAMP®
Solid conductor 0.08 … 2.5 mm² / 28 … 14 AWG
Fine-stranded conductor 0.34 … 2.5 mm² / 22 … 14 AWG
Strip length 9 … 10 mm / 0.35 … 0.39 inch
Physical data
Width 6 mm / 0.236 inch
Height 94 mm / 3.701 inch
Depth from upper edge of DIN-rail 97.8 mm / 3.85 inch
Mechanical data
Mounting type DIN-35 rail
Material data
Color light gray
Weight 35.3g
Environmental requirements
Surrounding air temperature (operation) -25 … +70 °C
Surrounding air temperature (storage) -40 … +85 °C
Relative humidity 5 … 95 % (no condensation permissible)
Operating altitude (max.) 2000m
Standards and specifications
Conformity marking CE
EMC immunity to interference EN 61000-6-2
EMC emission of interference EN 61000-6-4
Commercial data
Product Group 6 (Interface Electronics)
PU (SPU) 1 Each
Packaging type bag
Country of origin DE
GTIN 4045454470128
Customs tariff number 85437090300

 

Untuk informasi harga 857-800 WAGO Temperature signal conditioner for RTD sensors

Silahkan hubungi kami :

Telepon : 021-749-0079
Faksimile : 021-740-2915

WhatsApp : 0812-8110-2690
WhatsApp : 0813-9816-7208

Email : sparepartmesinindustri@gmail.com

https://www.sparepartmesinindustri.com/katalog
https://sparepartmesinindustri.blogspot.com